AV node ablation with pacing (pace-and-ablate)
Bedside summary
When rapid AF cannot be controlled by drugs and rhythm control (AADs and catheter ablation) has failed or is unsuitable, radiofrequency ablation of the AV node combined with permanent pacing — 'pace-and-ablate' — reliably controls the ventricular rate. It produces complete heart block, so the patient becomes permanently pacemaker-dependent and the procedure is irreversible. It is used most in older patients with permanent AF, often those who already have a device.
Red flags
- Irreversibility and pacemaker dependence — a dislodged or fractured RV lead with oversensing can cause asystole
- Rare early ventricular fibrillation and sudden cardiac death (~2.7%), mostly periprocedural — mitigated by the higher post-ablation pacing rate
- Standard RV apical pacing risks pacing-induced LV dysfunction / HF
Assessment
Differential diagnosis
- Refractory rapid AF/flutter despite maximal rate-control drugs
- Highly symptomatic or haemodynamically intolerant AF
- Tachycardia-induced cardiomyopathy
- Intact AV conduction 'overriding' a CRT device and reducing effective biventricular pacing
Investigations
- Confirm inadequacy of rate control at rest and on exertion before committing
- Echocardiography / LVEF — determines the pacing strategy (physiologic vs RV)
- Review any existing device (pacemaker / ICD / CRT)
Management
- Exhaust other options first (drug rate control, catheter ablation, rhythm control) — especially in younger patients.
- Counsel on lifelong pacemaker dependence and the risk of pacing-induced cardiomyopathy with RV apical pacing; obtain informed consent.
- Implant the pacing device before (or immediately before) AV node ablation; the ablation is acutely successful in >97%.
- Choose the device by profile: single-chamber VVIR (rate-adaptive) for permanent AF; dual-chamber DDDR with mode-switching for paroxysmal AF.
- If LVEF <=45% and >25% ventricular pacing is expected, use physiologic pacing (CRT or conduction-system pacing) rather than standard RV pacing.
- Pace at a higher rate (e.g. ~90 bpm) for the first ~3 months to reduce early post-ablation VF / sudden death risk.
Drugs & doses
Disposition
Complications & pitfalls
- Pacing-induced cardiomyopathy (RV pacing)
- Device / lead complications and infection in a pacing-dependent patient
- Catheter-ablation and device-implant procedural risks
Exam pearls
- Left bundle branch area pacing (LBBAP), a form of conduction-system pacing, is now the preferred strategy at many centres — narrower QRS and better LVEF and 6-minute walk than RV or biventricular pacing; His-bundle pacing and CRT are alternatives.
- In permanent AF with narrow QRS, AV junction ablation + CRT reduced mortality and HF hospitalisation vs pharmacologic rate control (HR 0.40 / 0.26 in randomised data).
- AV node ablation may be needed to restore effective biventricular pacing in CRT patients whose intact AV conduction lets AF 'override' the device (pacing <90%).
- In patients >=75 years, AV node ablation + pacing reduced arrhythmia-related healthcare use vs pulmonary vein isolation (HR 0.45) without excess mortality.
- Symptom and quality-of-life benefit is substantial and durable, largely from a slower, more regular ventricular rate.
Pace-and-ablate is an effective but irreversible last-resort rate-control strategy; with LVEF <=45% or when >25% pacing is expected, use physiologic (conduction-system / CRT) pacing, not RV apical pacing.
Disclaimer: Educational decision support for qualified clinicians and students — not a substitute for clinical judgement, local protocols or a full drug reference. Confirm every dose and contraindication against your formulary before prescribing.