Routine

Cardiac resynchronisation & conduction system pacing

CRT / CSP · Cardiac
Physician-written · Verified by three sets of doctors · Reviewed November 2026

Bedside summary

Cardiac physiologic pacing aims to restore or preserve synchronous ventricular contraction. Traditional cardiac resynchronisation therapy (CRT) uses biventricular pacing — a right atrial lead, a right ventricular lead and a left ventricular lead in the coronary sinus — to correct dyssynchrony in heart failure with reduced ejection fraction and bundle branch block. Conduction system pacing (His-bundle pacing and left bundle branch area pacing) instead captures the native conduction system for a more physiological activation, and is increasingly used when a coronary sinus lead fails or to avoid right-ventricular pacing-induced dyssynchrony.

Red flags

  • Rare ventricular tachycardia storm after CRT activation (proarrhythmia from altered repolarisation)
  • Loss of biventricular capture in a device-dependent patient (lead dislodgement, high thresholds)
  • Device-pocket infection or systemic infection seeding the leads
  • Acute lead perforation / tamponade or coronary sinus dissection at implant

Assessment

Differential diagnosis

  • Biventricular CRT (coronary sinus LV lead) — the established approach
  • Left bundle branch area pacing (LBBAP) — preferred conduction system pacing option
  • His-bundle pacing — physiological but technically demanding, higher/rising thresholds
  • CRT-P (pacing only) vs CRT-D (added defibrillation)

Investigations

  • ECG — QRS morphology and duration (left bundle branch block, pacing percentage); device interrogation for percent biventricular pacing
  • Echocardiogram — LV ejection fraction and reverse remodelling as a measure of response
  • Contrast venography before an upgrade (venous obstruction affects 10-30% of upgrade candidates)
  • Assessment for non-response (~30%): adherence, progressive heart failure, suboptimal lead position or inadequate pacing capture

Management

  • Select candidates with heart failure, reduced ejection fraction and electrical dyssynchrony (trial enrolment used LVEF <=35%, NYHA II-IV, LBBB with QRS >=140 ms in men / >=130 ms in women) on guideline-directed therapy
  • Aim for near-100% biventricular/physiological pacing — optimise AV delay, and in AF with fast rates raise the lower rate or consider AV node ablation to guarantee capture
  • Position the LV lead at the site of greatest electrical delay on the lateral/posterolateral wall, avoiding phrenic nerve capture and LV scar; quadripolar leads reduce phrenic stimulation
  • For non-responders, re-optimise pacing vectors to the narrowest non-apical QRS, consider multipoint pacing, or convert to conduction system (left bundle area) pacing

Drugs & doses

Continue and up-titrate guideline-directed heart-failure therapy before and after implant — CRT complements, it does not replace, medical therapy — confirm against local protocol / BNF

Disposition

Implant and follow in a device/heart-failure service; arrange regular device checks and heart-failure optimisation, and reassess non-responders for lead revision or conduction system pacing.

Complications & pitfalls

  • Coronary sinus/coronary vein trauma, pneumothorax, pocket haematoma and phrenic nerve pacing
  • LV lead dislodgement (~1.7%); failed LV lead placement in ~3-10%
  • Device malfunction (~5%) and lead problems (~7%) over follow-up; infection ~1-2%
  • Higher complication and mortality rates for upgrades than de novo implants

Exam pearls

  • Greatest benefit is in left bundle branch block, wider QRS, non-ischaemic cardiomyopathy and women; little or no benefit (possible harm) with a narrow QRS
  • Left bundle branch area pacing is now the preferred conduction system option — lower thresholds, higher implant success and better lead stability than His-bundle pacing
  • A high pacing percentage matters — undertreated AF or frequent ectopy that steals capture undermines CRT
  • CRT is also used to prevent pacing-induced cardiomyopathy in patients needing a high ventricular-pacing burden, including after AV node ablation

Resynchronisation only works if the patient actually gets it — secure LBBB-morphology candidates, place the LV lead well, and drive pacing towards 100%.

Disclaimer: Educational decision support for qualified clinicians and students — not a substitute for clinical judgement, local protocols or a full drug reference. Confirm every dose and contraindication against your formulary before prescribing.