Implantable defibrillator (ICD) storm
Device + arrhythmia · Cardiac
Physician-written · Verified by three sets of doctors · Reviewed November 2026
Bedside summary
Repeated ICD shocks from recurrent ventricular arrhythmia are distressing and harmful. Management targets the arrhythmia and its triggers while sedating the distressed patient.
Assessment
Investigations
- ECG and rhythm strip
- Electrolytes (K⁺, Mg²⁺)
- Troponin
- Device interrogation
- Identify reversible triggers
Management
- Treat reversible causes (ischaemia, electrolytes)
- Antiarrhythmic therapy (e.g. amiodarone)
- Sedation for distress
- Cardiology/electrophysiology input
- Consider a magnet per local protocol if inappropriate shocks
Drugs & doses
Amiodarone
Beta-blocker
Sedation
Disposition
CCU; electrophysiology.
Correct potassium and magnesium early in any ventricular-arrhythmia storm.
Disclaimer: Educational decision support for qualified clinicians and students — not a substitute for clinical judgement, local protocols or a full drug reference. Confirm every dose and contraindication against your formulary before prescribing.