High-flow nasal oxygen (HFNO)
HFNO · Critical Care / ICU
Physician-written · Verified by three sets of doctors · Reviewed November 2026
Bedside summary
Heated humidified high-flow nasal cannula delivers up to 60 L/min at a set FiO2, providing stable oxygenation, modest PEEP, dead-space washout and improved comfort. It is first-line non-invasive support for hypoxaemic (type 1) respiratory failure and useful peri-extubation, but requires close monitoring for failure.
Red flags
- ROX index below 3.85 at 2-12 h
- Rising respiratory rate or accessory muscle use
- Falling SpO2 despite FiO2 1.0
- Rising CO2 / falling conscious level
- Haemodynamic instability
Assessment
Differential diagnosis
- Pneumonia / viral pneumonitis
- ARDS (mild)
- Cardiogenic pulmonary oedema
- Post-operative hypoxaemia
- Immunocompromised hypoxaemia
- Post-extubation respiratory failure
Investigations
- ABG including P/F ratio
- Continuous SpO2 and respiratory rate
- ROX index calculation (SpO2/FiO2 ÷ respiratory rate)
- Chest imaging
- Serial lactate and work-of-breathing assessment
Management
- Confirm type 1 (hypoxaemic) failure with preserved or mild hypercapnia; HFNO is not first-line for significant hypercapnic failure
- Start flow at 50-60 L/min and titrate FiO2 to SpO2 target (usually 92-96%)
- Ensure heated humidification and well-fitting cannula smaller than nares
- Assess response within 30-60 min using work of breathing, respiratory rate and SpO2
- Calculate the ROX index at 2, 6 and 12 h; a value below 3.85 predicts failure and need for intubation
- Treat the underlying cause concurrently (antibiotics, diuresis, etc.)
- Encourage awake proning in selected cooperative hypoxaemic patients
- Do not delay intubation if there is no improvement or signs of fatigue
- For hypercapnia or NIV-responsive conditions consider NIV instead or alternately
- Wean flow then FiO2 as the patient improves
Drugs & doses
Oxygen titrated to FiO2 as per device
Treat underlying cause (e.g. antibiotics, furosemide 40-80 mg IV for pulmonary oedema)
Disposition
HDU/ICU setting with capacity for rapid escalation to intubation. Clear ceiling-of-care documentation and a failure-review timepoint.
Complications & pitfalls
- Delayed intubation and worse outcomes
- Aspiration
- Nasal trauma / dryness
- Failure to recognise hypercapnic failure
- Aerosol generation concerns
Exam pearls
- Use the ROX index to flag impending failure early rather than waiting for collapse
- HFNO reduces intubation vs standard oxygen in type 1 failure but does not replace timely intubation
- Each 10 L/min of flow adds roughly 0.5-1 cmH2O of airway pressure
- Awake proning may help in viral pneumonitis