Bedside summary

Extreme lung-protective concept: sub-deadspace tidal volumes (1–3 mL/kg) at 3–6 Hz oscillating around a high continuous distending pressure — effectively CPAP with superimposed oscillations clearing CO₂ by enhanced diffusion/mixing.

Red flags

  • 2020s update: routine adult HFOV showed NO benefit (OSCAR) and HARM (OSCILLATE) — abandoned as standard adult ARDS therapy; consider only exceptional rescue in experienced centres
  • Loss of spontaneous breathing and heavy sedation are real costs

Management

  • Historically rescue for refractory ARDS hypoxaemia; requires deep sedation ± paralysis
  • Set continuous distending pressure stepwise to an oxygenation/CXR target; frequency 3–6 Hz for CO₂
  • Volume-load before starting — haemodynamic compromise is common
  • Pneumothorax risk similar to conventional ventilation but harder to detect — scan/X-ray on deterioration

Of historical/rescue interest in adults — prone positioning and ECMO have superseded it.