Supraglottic airway devices in the difficult paediatric airway
Bedside summary
Supraglottic airways (SGAs) — laryngeal mask airway (LMA), i-gel, air-Q, CobraPLA — sit above the glottis and provide oxygenation and ventilation without entering the trachea. In a child with a difficult airway they can be life-saving when conventional intubation has failed, and should be available for every emergency paediatric intubation. They serve three roles: a rescue airway, a bridge between bag-mask ventilation and intubation, and a conduit through which the trachea can be intubated.
Red flags
- Likely to FAIL with airway obstruction (croup, asthma, epiglottitis) — airway pressure exceeds the mask seal and air leaks
- Likely to fail with distorted anatomy — laryngeal trauma/burns, congenital laryngeal anomalies
- If an SGA also fails to maintain SpO2 >90% (failed airway) → needle cricothyroidotomy (children ≤10–12 y) or surgical cricothyroidotomy (>10–12 y)
Assessment
Differential diagnosis
- LMA (incl. ProSeal/Supreme) — sized by weight; widely used across all paediatric sizes
- i-gel — non-inflatable thermoplastic gel cuff; integrated bite-block; gastric channel
- air-Q masked laryngeal airway — designed as an intubation conduit (<30 kg)
- CobraPLA — available in small sizes
Investigations
- Confirm adequate placement: chest rise, bilateral breath sounds, absence of gastric distension, and expired CO2 on capnography
- Reassess continuously — SGAs can be displaced and do not fully protect against aspiration
Management
- Select a weight-appropriate device; if weight is unknown, an LMA with an outer diameter roughly the size of the child's external ear (auricle) is a practical estimate.
- Ensure adequate sedation/anaesthesia (as for RSI) before insertion to block airway reflexes and prevent coughing, laryngospasm and vomiting.
- Insert per device technique; for the LMA in children <7 years the rotational technique gives higher first-attempt success with less laryngospasm and airway trauma (standard technique is acceptable in a rescue if more familiar).
- If ventilation is inadequate or there is a large leak, reposition with a jaw thrust or partial removal and reinsertion before abandoning the device.
- In a cannot-intubate situation, an SGA may be used as a conduit — pass a tube blindly or, better, guided by a flexible scope/optical or lighted stylet (air-Q <30 kg; intubating LMA [ILMA] only ≥30 kg); leave the device in place until a controlled setting.
Drugs & doses
Disposition
Complications & pitfalls
- Incomplete aspiration protection; vomiting/laryngospasm if inadequately anaesthetised
- LMA may fold the epiglottis down over the glottis, or catch on the vallecula, preventing ventilation
- i-gel: smaller sizes harder to seal and tends to be displaced upward — secure carefully
Exam pearls
- The i-gel uses a thermoplastic gel cuff (no balloon) that moulds to the larynx with body heat and is available for patients ≥2 kg; CobraPLA is available down to ~2.5 kg — confirm sizing against local protocol.
- A size 1 LMA is supported as a rescue airway and an alternative to bag-mask ventilation in term AND preterm neonates.
- The air-Q's wide ventilation tube admits the cuff and pilot balloon of a cuffed tracheal tube and has a ramp directing the tube to the glottis — a practical rescue-to-intubation bridge in children <30 kg.
- After training, first-attempt SGA success is ~90% or better, skill retention is high, and inexperienced providers place SGAs more reliably than tracheal tubes — pre-train on the device your unit stocks.
Have a weight-appropriate supraglottic airway ready for every emergency paediatric intubation — it rescues ventilation and can act as a conduit, but it neither protects fully against aspiration nor works with obstructed/distorted airways.
Disclaimer: Educational decision support for qualified clinicians and students — not a substitute for clinical judgement, local protocols or a full drug reference. Confirm every dose and contraindication against your formulary before prescribing.