Tension gas (auto-PEEP) in the ventilated asthmatic
Dynamic hyperinflation · Respiratory
Physician-written · Verified by three sets of doctors · Reviewed November 2026
Bedside summary
A ventilated severe asthmatic can develop breath stacking and dynamic hyperinflation, causing hypotension and apparent tension physiology. Disconnecting the circuit to allow exhalation is diagnostic and therapeutic.
Assessment
Investigations
- Recognise rising airway pressures with hypotension
- Disconnect to allow full exhalation
- Exclude a true pneumothorax
Management
- Disconnect the circuit and decompress the chest manually
- Reduce the respiratory rate and allow long expiration
- Exclude pneumothorax
- Optimise bronchodilation
- Critical-care management
Drugs & doses
Bronchodilators
Disposition
ICU.
If a ventilated asthmatic suddenly drops their BP, disconnect and let them exhale.
Disclaimer: Educational decision support for qualified clinicians and students — not a substitute for clinical judgement, local protocols or a full drug reference. Confirm every dose and contraindication against your formulary before prescribing.