Accidental endobronchial intubation

Mainstem tube · Anaesthesia & Perioperative
Physician-written · Verified by three sets of doctors · Reviewed November 2026

Bedside summary

The tracheal tube advancing into a main bronchus (usually the right) ventilates one lung, causing hypoxaemia, high airway pressure and unilateral chest signs. Withdrawal to a mid-tracheal position corrects it.

Assessment

Investigations

  • Unequal chest movement and absent breath sounds on one side
  • Rising airway pressure and falling SpO2
  • Check tube depth at the teeth (roughly 21 cm women, 23 cm men)
  • Capnography
  • Chest X-ray or fibreoptic confirmation if uncertain

Management

  • Give 100 percent oxygen
  • Auscultate both axillae and apices
  • Deflate the cuff and withdraw the tube 1-2 cm at a time while ventilating
  • Re-auscultate until bilateral breath sounds return
  • Re-inflate the cuff and re-secure the tube
  • Account for any change with patient position (flexion advances the tube)
  • Recruit atelectatic lung if desaturation persists

Drugs & doses

100 percent oxygen

Disposition

Continue case once bilateral ventilation confirmed.

Neck flexion advances a tube up to 2 cm toward the carina — re-check tube position after any head repositioning or table tilt.

Disclaimer: Educational decision support for qualified clinicians and students — not a substitute for clinical judgement, local protocols or a full drug reference. Confirm every dose and contraindication against your formulary before prescribing.