Accidental endobronchial intubation
Mainstem tube · Anaesthesia & Perioperative
Physician-written · Verified by three sets of doctors · Reviewed November 2026
Bedside summary
The tracheal tube advancing into a main bronchus (usually the right) ventilates one lung, causing hypoxaemia, high airway pressure and unilateral chest signs. Withdrawal to a mid-tracheal position corrects it.
Assessment
Investigations
- Unequal chest movement and absent breath sounds on one side
- Rising airway pressure and falling SpO2
- Check tube depth at the teeth (roughly 21 cm women, 23 cm men)
- Capnography
- Chest X-ray or fibreoptic confirmation if uncertain
Management
- Give 100 percent oxygen
- Auscultate both axillae and apices
- Deflate the cuff and withdraw the tube 1-2 cm at a time while ventilating
- Re-auscultate until bilateral breath sounds return
- Re-inflate the cuff and re-secure the tube
- Account for any change with patient position (flexion advances the tube)
- Recruit atelectatic lung if desaturation persists
Drugs & doses
100 percent oxygen
Disposition
Continue case once bilateral ventilation confirmed.
Neck flexion advances a tube up to 2 cm toward the carina — re-check tube position after any head repositioning or table tilt.