Airway exchange catheter — tube exchange
AEC · Anaesthesia & Perioperative
Physician-written · Verified by three sets of doctors · Reviewed November 2026
Bedside summary
Using a hollow semi-rigid catheter to maintain airway access while swapping a tracheal tube or trialling extubation of a high-risk airway. The catheter allows reintubation and oxygen delivery.
Assessment
Investigations
- Reason for exchange or at-risk extubation
- Correct catheter length and depth markings
- Oxygenation reserve
- Capnography on the catheter if ventilating
- Backup intubation equipment
Management
- Pre-oxygenate fully before exchange
- Pass the catheter through the existing tube to a safe depth (no deeper than 25 cm)
- Hold depth constant and remove the old tube
- Railroad the new tube over the catheter with laryngoscopy to lift tissue
- Confirm position with capnography before removing the catheter
- For at-risk extubation, leave the catheter in situ and tape securely
- Give oxygen via nasal cannula alongside
- Avoid high-pressure jet ventilation to prevent barotrauma
Drugs & doses
Oxygen: insufflation 1-2 L/min only if essential
Lidocaine: 1-1.5 mg/kg IV to reduce cough
Maintain sedation if catheter left for extubation
Disposition
ICU/recovery; monitor the retained catheter.
Keep the tip above the carina and avoid jet ventilation to prevent barotrauma (DAS extubation guideline).