Endovascular repair of infrarenal abdominal aortic aneurysm (EVAR)
Bedside summary
EVAR excludes an infrarenal abdominal aortic aneurysm (AAA) by deploying a fabric-covered stent graft (endograft) through femoral access; on deployment it seals against the aortic wall at the neck proximally and the iliac arteries distally, excluding the sac from aortic flow and pressure. Fixation relies solely on the radial force of the graft (no sutures), so anatomic suitability is the key determinant of durable success. Compared with open repair it markedly lowers perioperative morbidity and mortality (no aortic clamping/exposure) and now accounts for roughly half of AAA repairs. The early survival advantage erodes to equivalence with open repair within 1–2 years, and lifelong surveillance is mandatory because endografts can fail late.
Red flags
- Type I or type III endoleak — pressurises the sac and carries ongoing rupture risk; treat promptly
- Sac enlargement on surveillance — implies a persistent leak or endotension
- Graft migration or limb occlusion — may present as acute limb ischaemia
- Post-EVAR aortic rupture — late catastrophic failure of exclusion
- Haemodynamic instability during access — suspect iliac avulsion/rupture (more common in females / small calcified iliacs)
Assessment
Differential diagnosis
- Open surgical repair — preferred where anatomy is unsuitable or in younger low-risk patients
- Fenestrated/branched endograft — for short-necked, juxtarenal or suprarenal AAA
- Chimney/parallel (snorkel/periscope) grafting — to preserve visceral/renal branches
- Conservative surveillance — asymptomatic AAA <5.5 cm not meeting repair criteria
- Aorto-uni-iliac (AUI) device + femoro-femoral crossover — hostile contralateral iliac access or ruptured AAA
Investigations
- CT angiography abdomen/pelvis, ≤2.5 mm cuts with 3D reconstruction — the standard for feasibility and endograft sizing (aortic neck diameter/length/angulation, iliac diameter/tortuosity, sac diameter)
- Intravascular ultrasound (IVUS) — accurate intra-operative sizing; useful adjunct in kidney impairment
- MR angiography — alternative for planning; gadolinium a relative contraindication in renal dysfunction
- Digital subtraction angiography — for intra-operative/emergency sizing (ruptured AAA), not routine pre-EVAR
- Baseline renal function — contrast and suprarenal fixation both threaten the kidneys
Management
- Confirm anatomic suitability: aortic neck length ≥10 mm, angulation ideally <60°, suitable external iliac calibre (≈≥7 mm for most delivery sheaths)
- Full cardiac/pulmonary/renal risk assessment as if for open repair (conversion remains possible; coronary disease is the leading cause of late death)
- Bilateral common femoral access — percutaneous (large-bore closure devices) or surgical cutdown; iliac conduit if access vessels too small
- Systemic heparinisation before device insertion
- Deploy main bifurcated body with proximal markers just below the lowest renal artery, cannulate the contralateral gate, deploy iliac limbs, then balloon-mould seal zones and junctions
- Completion aortography to confirm renal patency and detect endoleak; treat immediate type I/III leaks with further ballooning or extension cuffs
- Enrol in lifelong imaging surveillance (1 month, then annually)
Drugs & doses
Disposition
Complications & pitfalls
- Endoleak (types I–V) — persistent sac perfusion; overall complication rate ≈10%
- Postimplantation syndrome — transient flu-like illness, fever, leukocytosis, reactive effusions (≈13–60%)
- Contrast-induced acute kidney injury; renal infarction from suprarenal struts/embolisation
- Access-site / iliofemoral vascular injury
- Deep vein thrombosis (≈5% despite prophylaxis)
- Distal (eg, pelvic/limb) embolisation
- Conversion to open repair (<2% in contemporary practice)
Exam pearls
- Oversize the endograft ≈15–20% above the measured aortic neck diameter to generate enough radial force to prevent migration; devices reach 36 mm, treating necks up to ~32 mm — confirm against local protocol / BNF
- Proximal neck length <10 mm, angulation >60°, heavy thrombus/calcification or reverse (conical) taper all threaten the seal and raise type I endoleak risk
- Type II endoleak (retrograde branch flow) is usually benign — selective, not routine, intervention; type I and III leaks need repair
- Pre-emptive inferior mesenteric / hypogastric embolisation reduces type II endoleak when distal iliac extension is needed
- 30-day mortality is lower than open repair (≈1.6% vs 4.8%) but all-cause survival converges by 1–2 years
- Surveillance: CT angiography (or unenhanced CT + duplex) at 1 month, then annually; duplex can replace CT once stable with no endoleak
- Inability to comply with lifelong surveillance is a relative contraindication
EVAR trades lower early morbidity and mortality for a mandatory lifelong surveillance commitment — the endograft can fail late through endoleak, migration, sac growth and rupture.
Disclaimer: Educational decision support for qualified clinicians and students — not a substitute for clinical judgement, local protocols or a full drug reference. Confirm every dose and contraindication against your formulary before prescribing.