Anaesthesia for MRI
MRI anaesthesia · Anaesthesia & Perioperative
Physician-written · Verified by three sets of doctors · Reviewed November 2026
Bedside summary
Providing anaesthesia within the strong magnetic field of the MRI scanner, where ferromagnetic hazards and remote access dominate safety. All equipment and implants must be checked for MR compatibility.
Assessment
Investigations
- MR-safety screening of patient and all staff
- Implant and device compatibility check
- MR-conditional monitoring and ventilator
- Access and visualisation plan during scanning
- Hearing protection and temperature
Management
- Screen everyone entering the controlled area for ferromagnetic items
- Check patient implants against the MR-safety database
- Use only MR-conditional monitoring, ventilator and pumps
- Secure the airway before entering the bore for difficult-access patients
- Site long infusion and monitoring lines through the waveguide
- Monitor from the control room with clear sight lines
- Protect hearing and avoid burns from looped cables
- Have a plan to evacuate from the magnet in an emergency
Drugs & doses
Propofol: TCI for maintenance with MR-safe pumps
Sevoflurane: via an MR-conditional anaesthetic machine
Remifentanil: TCI as required
Disposition
MR-safe recovery area.
Never take a ferromagnetic object into the scanner; evacuate the patient from the bore to resuscitate (AAGBI MRI guidance).
Disclaimer: Educational decision support for qualified clinicians and students — not a substitute for clinical judgement, local protocols or a full drug reference. Confirm every dose and contraindication against your formulary before prescribing.