Endotracheal tube obstruction under anaesthesia
Blocked tube · Anaesthesia & Perioperative
Physician-written · Verified by three sets of doctors · Reviewed November 2026
Bedside summary
The tracheal tube can obstruct from kinking, biting, secretions, blood, a herniated cuff or a foreign body, causing rising pressure and falling tidal volume. Rapid exclusion then tube change restores ventilation.
Assessment
Investigations
- Capnography (attenuated or absent trace)
- Pass a suction catheter to test and clear the lumen
- Inspect for kinking, biting and cuff herniation
- SpO2 and airway pressures
- Fibreoptic inspection if available
Management
- Call for help and give 100 percent oxygen
- Hand ventilate to assess resistance
- Insert a bite block if the patient is biting the tube
- Pass a suction catheter; if it will not pass, the tube is obstructed
- Deflate the cuff in case of cuff herniation
- If ventilation remains impossible, remove and replace the tube or re-oxygenate by facemask/supraglottic device
- Use a tube exchanger or re-laryngoscopy for the replacement
Drugs & doses
100 percent oxygen
Propofol: 0.5-1 mg/kg IV to deepen before tube change
Suxamethonium 1 mg/kg or rocuronium 1 mg/kg if relaxation needed
Disposition
Continue once a patent airway is confirmed by capnography.
Inability to pass a suction catheter is the quickest bedside confirmation of tube obstruction — do not hesitate to remove a tube you cannot ventilate through.
Disclaimer: Educational decision support for qualified clinicians and students — not a substitute for clinical judgement, local protocols or a full drug reference. Confirm every dose and contraindication against your formulary before prescribing.