Bedside summary

Placement of a double-lumen tube to separate the two lungs for thoracic surgery and to protect against cross-contamination. Correct positioning is confirmed clinically and bronchoscopically.

Assessment

Investigations

  • Side and size selection (left DLT default; 37-41 Fr by sex/height)
  • Chest imaging for airway anatomy
  • Fibreoptic bronchoscope availability
  • Baseline arterial oxygenation
  • Reason for isolation (surgery, bleeding, lavage)

Management

  • Choose a left-sided DLT unless left bronchial surgery
  • Intubate with the bronchial tip concave-anterior then rotate 90 degrees
  • Advance until moderate resistance or to depth by height
  • Inflate tracheal then bronchial cuffs (1-2 mL)
  • Confirm isolation by sequential clamping and auscultation
  • Verify position with the fibrescope (blue cuff just below carina)
  • Re-check position after lateral positioning
  • Suction each lumen independently

Drugs & doses

Propofol: 1.5-2.5 mg/kg IV induction
Rocuronium: 0.6-1 mg/kg IV
Remifentanil: TCI 3-5 ng/mL
Lidocaine: 1 mg/kg IV to reduce carinal cough

Disposition

Theatre; verify position after turning the patient.

Always confirm DLT position bronchoscopically and again after repositioning (Miller 9e).