Operating theatre fire safety

Theatre safety · Anaesthesia & Perioperative
Physician-written · Verified by three sets of doctors · Reviewed November 2026

Bedside summary

Surgical fires arise when the fire triad of oxidiser, fuel and ignition source coincides, especially during airway or head-and-neck surgery with diathermy or laser in an oxygen-enriched field.

Assessment

Investigations

  • Identify high-risk cases (airway/head-and-neck with diathermy/laser)
  • Oxidiser concentration in the surgical field
  • Alcohol-based prep drying time
  • Availability of saline and a fire plan
  • Laser-safe tube for airway laser surgery

Management

  • Assess fire risk before high-risk surgery
  • Minimise the inspired oxygen concentration in the field
  • Avoid nitrous oxide which also supports combustion
  • Allow alcohol-based skin prep to dry fully
  • Use a laser-resistant tube for airway laser surgery
  • Keep saline and a fire plan immediately available
  • If an airway fire occurs, stop gases, remove the tube and flood with saline, then re-establish the airway

Drugs & doses

No drugs — safety procedure
Flood an airway fire with saline/water
Re-establish the airway and ventilate after extinguishing

Disposition

Theatre; manage any burn injury and debrief.

Reduce the oxidiser, separate ignition from fuel and, for an airway fire, stop gases and remove the burning tube immediately (AAGBI/APSF fire safety).

Disclaimer: Educational decision support for qualified clinicians and students — not a substitute for clinical judgement, local protocols or a full drug reference. Confirm every dose and contraindication against your formulary before prescribing.