Bedside summary
Replacing alveolar nitrogen with oxygen before induction to extend the safe apnoea time, with nasal oxygen continued during laryngoscopy. Essential wherever desaturation is likely.
Assessment
Investigations
- End-tidal oxygen target (greater than 0.85-0.9)
- Mask seal assessment
- Functional residual capacity factors (obesity, pregnancy)
- SpO2 baseline
- Planned airway difficulty
Management
- Position head-up or ramped in the obese patient
- Apply a tight-fitting mask with high fresh gas flow
- Ask for 8 vital-capacity breaths or 3 minutes of tidal breathing
- Confirm end-tidal O2 greater than 0.85 before induction
- Leave nasal cannulae running at 5-15 L/min through apnoea
- Consider high-flow nasal oxygen for prolonged laryngoscopy
- Avoid prolonged apnoea without oxygen flow
Drugs & doses
Oxygen: 100% at 10-15 L/min via tight mask
Nasal oxygen: 5-15 L/min for apnoeic oxygenation
High-flow nasal O2: up to 70 L/min (THRIVE technique)
Disposition
Proceed to induction once denitrogenated.
Apnoeic oxygenation via nasal prongs meaningfully prolongs safe apnoea time (DAS).