Bedside summary

A cuffed perilaryngeal device with a gastric drain channel used for airway maintenance in suitable elective cases. Second-generation devices allow higher seal pressures and gastric access.

Assessment

Investigations

  • Suitability (fasting, low aspiration risk, body habitus)
  • Correct size by weight
  • Seal and leak assessment after insertion
  • Gastric port patency
  • Positive-pressure requirement

Management

  • Select size by weight and check the cuff
  • Achieve adequate depth of anaesthesia
  • Insert along the palate until resistance
  • Inflate the cuff to 60 cmH2O or less
  • Confirm ventilation and a square capnograph trace
  • Pass a gastric tube through the drain channel
  • Secure the device and support with a bite block
  • Convert to a tracheal tube if the seal is inadequate

Drugs & doses

Propofol: 2-3 mg/kg IV (deeper than for intubation)
Fentanyl: 1 microgram/kg IV to obtund response
No routine neuromuscular blocker required

Disposition

Recovery; remove awake or deep per protocol.

Keep cuff pressure at or below 60 cmH2O to limit pharyngeal morbidity (AAGBI).