Standard anaesthetic monitoring set-up

Monitoring · Anaesthesia & Perioperative
Physician-written · Verified by three sets of doctors · Reviewed November 2026

Bedside summary

Establishing the minimum monitoring required before inducing anaesthesia, present continuously until recovery. These standards underpin the early detection of every critical incident.

Assessment

Investigations

  • Pulse oximeter function
  • Non-invasive blood pressure and ECG
  • Capnography and agent analyser
  • Airway pressure and disconnection alarms
  • Nerve stimulator and temperature probe availability

Management

  • Attach the monitor and confirm all alarms are active before induction
  • Apply pulse oximetry and ECG
  • Set non-invasive blood pressure to cycle appropriately
  • Connect capnography before airway instrumentation
  • Enable the oxygen analyser and agent monitor
  • Add neuromuscular and depth monitoring when a relaxant or TIVA is used
  • Place a temperature probe for cases over 30 minutes
  • Never leave an anaesthetised patient unattended

Drugs & doses

—

Disposition

Continues from induction to recovery handover.

AAGBI standards: pulse oximetry, capnography, ECG, blood pressure, agent and oxygen analysis are mandatory (AAGBI minimum monitoring).