Tracheal cuff pressure management
Airway safety · Anaesthesia & Perioperative
Physician-written · Verified by three sets of doctors · Reviewed November 2026
Bedside summary
Maintaining tracheal tube cuff pressure within a safe range protects against both aspiration (underinflation) and tracheal mucosal ischaemia (overinflation). A manometer gives objective control.
Assessment
Investigations
- Cuff manometer reading
- Audible leak at the set pressure
- Capnography/ventilation for leak
- Nitrous oxide use (diffuses into the cuff)
- Signs of aspiration
Management
- Inflate the cuff to just seal the airway
- Measure the pressure with a manometer rather than by feel
- Keep the pressure within the safe range
- Recheck after nitrous oxide exposure (cuff expands)
- Avoid overinflation to prevent mucosal ischaemia
- Avoid underinflation to prevent aspiration and leak
- Reassess after repositioning the patient
Drugs & doses
No drugs — airway procedure
Target cuff pressure 20-30 cmH2O (ideally about 25)
Release nitrous-oxide-induced overpressure with a manometer
Disposition
Theatre / ICU.
Cuff pressures above 30 cmH2O risk tracheal mucosal ischaemia; nitrous oxide diffuses in and raises the pressure (Miller).